An AC & generator is used to supply power (electricity) to anything that requires Alternating Current supply. This could be lights and fans in your home or large motors and air conditioning systems in an industry. We help you to have both facilities at your home
Saltel Backed by a team of qualified engineers and partnerships with leading manufacturers of AC-Air Conditioning equipment such as LG AC, Samsung AC, Voltas AC, Godrej AC, Whirlpool AC, Carrier AC, Toshiba and Panasonic. SALTEL developed proven experience in AC-Air Conditioning services from advisory, to implementation and after-implementation support to help enterprises achieve highly available, scalable, secure, self-healing and cost-effective AC architectures.
Air conditioning is the process of removing heat and moisture from the interior of an occupied space to improve the comfort of occupants. Air conditioning can be used in both domestic and commercial environments. This process is most commonly used to achieve a more comfortable interior environment, typically for humans and other animals; however, air conditioning is also used to cool and dehumidify rooms filled with heat-producing electronic devices, such as computer servers, power amplifiers, and to display and store some delicate products, such as artwork.
Best Air Conditioner / AC brands in Rwanda all provided by Saltel such as Hitachi, Daikin and Blue Star also offer great energy efficient models and typically rank high in our top rankings (based on BEE data). Other brands that are really good include: LG AC, Samsung AC, Voltas AC, Godrej AC, Whirlpool AC, Carrier AC, Toshiba and Panasonic
We can accommodate for any budget, providing Best Air Conditioner / AC brands solutions to all domestic, commercial, retail and industrial customers from home or offices!
Electrical generator power supply is an electrical apparatus that provides emergency power to a load when the input power source or mains power fails. ... It is a type of continual power system.
A standby Generator resorts to Electricity backup power in the event of common power problems such as a blackout, voltage sag, or voltage surge. When incoming utility power drops below or surges above safe voltage levels, the automated Generator switches to DC battery power and then inverts it to AC power to run connected the building in a light of motion.
The working principle of the Air conditioner or AC is collecting hot air from a gives spaces and processing it to release cool air into the same space where the hot air had originally been collected. This process is done through the 5 steps such as the evaporator, compressor, condenser, expansion valve, Refrigerant.
Your air conditioning unit uses chemicals that convert from gas to liquid and back again quickly. These chemicals transfer the heat from the air inside your property to the outside air. The AC unit has three key parts. The compressor squeezes this gas/fluid, and the molecules in the liquid are packed closer together
A generator is a highly technical product, and each model has unique features and specifications. As a result, choosing one that is suitable for your needs can be a challenge. This article provides an in-depth review of our top 10 generators to help you make an informed decision.
Saltel Backed by a team of qualified engineers in who has many years of experience in repairing Generators. SALTEL developed proven experience in Generators repair and supply services from advisory, to implementation and after-implementation support to help enterprises achieve highly available, scalable, secure, self-healing and cost-effective of Generator Power Backup architectures.
The engine oil must be checked while shutting down the generator at regular intervals using a dipstick. Allow the oil in the upper portions of the engine to drain back into the crankcase and follow the engine manufacturer’s recommendations for API oil classification and oil viscosity. Keep the oil level as near as possible to the full mark on the dipstick by adding the same quality and brand of oil.
Check the coolant level during shutdown periods at the specified interval. Remove the radiator cap after allowing the engine to cool, and, if necessary, add coolant until the level is about 3/4 in. Heavy-duty diesel engines require a balanced coolant mixture of water, antifreeze, and coolant additives. Inspect the exterior of the radiator for obstructions, and remove all dirt or foreign material with a soft brush or cloth with caution to avoid damaging the fins.
Diesel is subject to contamination and corrosion within a period of one year, and therefore regular generator set exercise is highly recommended to use up stored fuel before it degrades. The fuel filters should be drained at the designated intervals due to the water vapor that accumulates and condenses in the fuel tank.
In case there are leaks along the exhaust line which usually occurs at the connection points, the welds and the gaskets; they should be repaired immediately by a qualified technician. Especially 24 hrs before using your generators. “For standby generators for example you need to have your units serviced 150hrs on average. However if the generator is used constantly the hours go up much quicker and in more regular intervals,” she adds.